G-Logo


Ex PC-Workstations, Ex-PCs

Ex Automation technology

Ex-p Pressurized enclosures


D122.A D122.PA D122.Z DM110 TA125
D122.PABlockdiagramDimensionsPropertiesTech.dataType.codeDownload

Fieldbus indicator D122.PA/FF -Technical Details

    D122.PA/FF
General

Mounting

Ex area, Zone 1 and Zone 21

Device group II 2 (1) G / D

Ex-protection

II 2 (1) G; Ex ib IIC T6/T5 Gb
II 2 (1) D; Ex ib IIIC T135°C Db

Certificates

TÜV 99 ATEX 1488
IECEx TUN 14.0011

Ex- limits

See EC- type certificate

Data exchange according to 61158-2

Ambient temperature

-10°C ...+45°C at T6
 -10°C ...+60°C at T5
Devices for -20°C Ta on demand

Humidity  5-95%, non-condensing
Housing

Dimensions

140 x 140 x 71 mm

Protection class

IP 66 acc. to EN 60529

Housing material

Aluminium, lacquered

Weight

900g

Color

RAL 7035

Indication

Display

5-figure LCD-7-Segment

additional Bargraph 41 Segments

Figure height

30 mm

Range -99999 ... + 99999
Dimensions symbols

Selectable with defined symbols

Decimal point

Selectable by keyboard

Alarm monitoring terminal limits

Yes

Connection power supply

loop powered, on field bus 9 .. 30V

power consumption

< 10 mA

  last modified: 12.02.2020